KMT Series Thermal Vacuum Chamber

The KMT Series Thermal Vacuum Chambers are designed to simulate a high-vacuum space environment with vacuum levels exceeding 10⁻³ Pa, enabling realistic test under cold-black space conditions. The system features a temperature-controlled baseplate, which significantly reduces stabilization time under vacuum, and an intelligent temperature monitoring and data logging system for real-time tracking of the test process. These chambers are widely used in the aerospace sector for environmental simulation and reliability test of materials, electronic components, assemblies, subsystems, and small-scale spacecraft or instruments.

2. KMT热真空试验箱.png
Features
  • Ultra-high vacuum performance.
  • Multi-mode precision temperature control.
  • Advanced intelligent monitoring and data recording.
Technical Specifications

Chamber Volume (Hot Sink Zone): 400L to 2650L (φ800–φ1500 × L800–L1500 mm)

Cold Plate Dimensions (W×L, mm): 600 × 600 to 1200 × 1200

Temperature Range (Hot Sink / Cold Plate): -40 / -70°C to +150°C

Heating/Cooling Rate (°C/min): 1 to 5°C/min

Temperature Fluctuation (°C): ±1°C / ±2°C (after 2h at setpoint)

Temperature Uniformity (°C): ±2°C / ±3°C (after 2h at setpoint)

Ultimate Pressure (Pa): ≤ 5 × 10⁻⁴ Pa / ≤ 5 × 10⁻⁵ Pa

Working Pressure (Pa): ≤ 1.33 × 10⁻³ Pa / ≤ 1.33 × 10⁻⁴ Pa

Vacuum Pumping System(configurable): Rotary vane pump, Roots pump, Screw pump, Molecular pump, Cryogenic pump

Pumping Time: From atmospheric pressure to 1.33 × 10⁻³ Pa ≤ 3 hours

Pressure Tolerance: >133 Pa: ≤ ±10%;  133–0.133 Pa: ≤ ±25%; <0.133 Pa: ≤ ±80%