Static and Fatigue Performance Testing

Static and fatigue performance tests can determine the stress distribution and deformation pattern of a structure under a certain static or fatigue load; determine the stiffness and stability of the structure; determine the maximum load-bearing capacity, i.e., strength; evaluate the reasonableness of the structure to withstand static loads from a force-bearing perspective; and verify the reliability of theoretical analysis and calculation methods.

静载和疲劳性能试验.jpg
Test Items

Static load test, compressive static load test, pull-out static load test, horizontal static load test, static strength, static stiffness, high-load fatigue test, structural fatigue test, fatigue crack propagation test/residual life test, conventional fatigue life test, etc.


Test Indicator Capabilities

The laboratory has a workshop area of 3374m², a 1000m² load-bearing floor grid, a 6-meter load-bearing wall, a 600 L/min 28 MPa hydraulic pump station, a 64-channel MTS all-digital coordinated loading system, and a static data acquisition system with over a thousand channels. It can conduct static and fatigue performance tests for products in automotive, construction, rail transit, aerospace, and marine industries.

1) MTS Coordinated Loading System

 Analog input and output module (±10V)

 Valve control module, valve control signal: 25mA, 50mA, 75mA

 16-bit resolution, 1,024Hz sampling rate

 Accuracy: ≤±0.1% F.S

2) Hydraulic Power Unit System

 Rated flow: 100 L/min to 600 L/min, max. 600 L/min

 Rated working pressure: 21 MPa

 Noise: ≤72 dB

 Tank volume: 2,600 L

 Motor power: 45 kW * 6 units

 Working medium: LHM46 anti-wear hydraulic oil

3) Data Acquisition and Analysis System

 Input modes: GND, SIN-DC, DIF-DC, AC, SIN-IEPE, DIF-IEPE

 Voltage range: ±10V to ±5mV

 Voltage indication error: 0.3% F.S

 Strain range: ±100,000με, ±10,000με, ±1,000με

 Strain indication error: 0.3% red ± με

 Bridge modes: Half-bridge (four-wire supply), full-bridge (four-wire supply), three-wire 1/4 bridge (120Ω)

 Bridge voltage (DC): 2V, 5V, 10V, 24V selectable, max output current 50mA

 Bridge voltage accuracy: 0.1%