Low Air Pressure Testing

The laboratory is equipped with high-low temperature, damp heat, low air pressure test chambers ranging from 0.5m³ to 110m³. The pressure range extends from normal atmospheric pressure (101 kPa) to low pressure (as low as 0.5 kPa). The temperature control range is typically -70°C to +150°C, with some equipment reaching up to 300°C. The laboratory can conduct high-temperature low pressure, low-temperature low pressure, low pressure, and rapid decompression tests.

低气压试验.jpg
Test Indicator Capabilities

 Temperature Range: -70°C to +300°C;

 Pressure Range: 0.5 kPa to 101 kPa;

 Decompression Time: Normal pressure to 1 kPa ≤ 30 min;

 Rapid Decompression: ≤ 15 s;

 Volume: 0.5m³ to 110m³.


Test Standards

 IEC 60068-2-13, IEC 60068-2-39, etc.