Vibration Testing
The laboratory is equipped with electrodynamic vibration test systems with a maximum force of 1,176 kN and hydraulic vibration test systems of 10t, 30t, and 50t. The electrodynamic systems have a wide frequency range, effectively simulating high-frequency vibrations, with some high-frequency systems reaching up to 6,000 Hz. The hydraulic systems have a narrower frequency range but can generate large displacements at low frequencies with strong load capacity, suitable for simulating earthquakes and low-frequency vibrations of large machinery. We can perform sine vibration (sweep, fixed frequency, resonance search), random vibration, combined vibration (sine-on-random, random-on-random), and road spectrum simulation.
Electrodynamic Vibration Test System Capabilities:
Thrust: Max 120t (1,176 kN);
Frequency Range: 1 to 2,000 Hz (with a dedicated 6,000 Hz high-frequency system available);
Max. Acceleration: 150 g;
Max. Velocity: 2.4 m/s;
Max. Displacement: 100 mm;
Max. Load: 10,000 kg;
Table Size: Max. 4,500 mm × 4,500 mm.
Hydraulic Vibration Test System Capabilities:
Thrust: Max. 50t (490 kN);
Range: 0.1-60 Hz (Sine), 1-200 Hz (Random);
Max. Displacement (P-P): 450 mm;
Max. Velocity: 1 m/s (Sine), 4 m/s (Shock);
Max. Acceleration: 5 g (Sine), 20 g (Shock);
Max. Load: 30,000 kg;
Table Size: 4,000 mm × 4,000 mm.
IEC 60068-2-6, IEC 60068-2-64,RTCA-DO-160G, etc.
Related Solutions
Related Test Equipments
-
DIC Series Electrodynamic Vibration Test System -
DT Series Large-Table Electrodynamic Vibration Test System -
DF Series High-Frequency Electrodynamic Vibration Test System -
MAV Series Three-Axis Electrodynamic Vibration Test System -
STHV Series Vibration–Temperature–Humidity–Salt Spray Combined Environmental Test System -
ATHV Series Vibration–Temperature–Humidity–Low Pressure Combined Environmental Test System -
THV Series Vibration–Temperature–Humidity Combined Environmental Test System